Product overview: Fluke ii900 Industrial Acoustic Imager
Equipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Industrial Acoustic Imager (Sonic Industrial Imager) enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments. Specifically designed for noisy production facilities the new SoundSight technology is simple to learn and easy to implement. The 7 LCD touchscreen overlays a SoundMap on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. For the first time, you can quickly and easily identify the air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes. Never leave air leaks unattended again.
Specifications: Fluke ii900
Industrial Acoustic Imager |
|
Sensors |
|
# of microphones |
64 digital MEMS microphones |
Frequency band |
2 kHz to 52 kHz |
Sound pressure sensitivity |
Detects a 0.005 CFM leak at 100PSI
from up to 32.8 feet |
Operation distance range |
0.5 to > 70 meters (1.6 to >
164 feet)* |
Field of View |
63 ° ± 5 ° |
Minimum Frame Rate |
25 FPS |
Built-in digital camera (visible
light) |
|
Field of View (FOV) |
63 ° ± 5 ° |
Focus |
Fixed lens |
Zoom |
3 x Digital Zoom |
Display |
7 inch LCD with backlight,
under-sunlight readable |
Resolution |
1280 x 800 (1,024,000 pixels) |
Touchscreen |
Capacitive |
Acoustic Image |
Yes, SoundMap™ image |
Asset ID |
QR code based asset ID identification |
Photo notes |
Up to 4 photos notes for reference |
Source |
Show single or multiple sources |
Profile |
Preset capture profiles |
Image storage |
|
Storage capacity |
20 GB |
Image format |
Blended visual and SoundMap™.JPG or
.PNG |
Video format |
Blended visual and SoundMap™.MP4 |
Video length |
5 minutes maximum |
Digital export |
USB-C for data transfer |
Acoustic Measurements |
|
Measurement range |
29.3 dB to 119.6 dB SPL (±2 dB) at 2
kHz |
Auto max/min dB gain |
Auto or manual, user selectable |
Frequency band selection |
User selectable through user-made
presets or manual entry |
Software |
|
Ease of use |
Intuitive user interface |
Trend graphs |
Frequency and dB scale |
Spot markers |
dB level reading at center point of
the image |
Battery |
|
Batteries (field-replaceable,
rechargeable) |
Rechargeable Li-ion |
Battery life |
6 hours (product includes spare
battery) |
Battery charging time |
3 hours |
Battery charging system |
External charger |
General Specifications |
|
Standard palettes |
3: Grayscale, Ironbow, Blue-Red |
Operating Temperature |
0 °C to 40 °C (32 °F to 104 °F) |
Storage Temperature |
-20 °C to 70 °C (-4 °F to 158 °F)
Without batteries |
Relative humidity |
10 % to 95 % non-condensing |
Size (H x W x L) |
186 mm x 322 mm x 68 mm (7.3 inches x
12.7 inches x 2.7 inches) |
Weight (battery included) |
2.15 kg (4.74 lbs) |
Ingress Protection (IP) |
IP40 protection |
Warranty |
2 year |
Self-diagnostic notification |
Array-health test to identify when
microphone array needs attention |
Supported languages |
Dutch, English, Finish, French,
German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified
Chinese, Spanish, Swedish, Traditional Chinese |
RoHS compliant |
Yes |
Safety |
|
General Safety |
IEC 61010-1 |
Electromagnetic Compatibility (EMC)
International |
IEC 61326-1: Portable Electromagnetic
Environment IEC 61326-2-2 |
Korea (KCC) |
Class A Equipment (Industrial
Broadcasting & Communication) |
USA (FCC) |
47 CFR 15 subpart B. This product is
considered an exempt device per clause 15.103. |
Models: Fluke ii900 Industrial Acoustic Imager
Fluke ii900 Sonic Industrial Imager
Includes: